usb: misc: Resume IPC interface on receiving interrupt complete callback
usb_autopm_get_interface_no_resume() called from interrupt URB complete callback only increments PM usage count but does not change the runtime PM status. Consider a case where interrupt complete callback is called and at the same time usb_runtime_idle() for USB device is called after all interfaces are suspended. usb_runtime_idle() will return -EBUSY as the PM usage count is non-zero. When the IPC bridge driver finishes with the read URB, it calls usb_autopm_put_interface_async() which returns -EAGAIN, as IPC interface runtime PM status is already RPM_SUSPENDED. Since the usb_runtime_idle() call fails, the autosuspend timer will not be re-armed and hence the idle() callback for the USB device will never be called. So to fix this, in interrupt completion callback, replace usb_autopm_get_interface_no_resume() with usb_autopm_get_interface_async() which will not only increment the PM usage count but also change the runtime PM status of IPC interface and if there is a suspend in progress, as this is an asynchronous call, it just returns -EINPROGRESS and the IPC bridge RX state machine ensures that the suspend is aborted. CRs-Fixed: 701097 Bug: 18528627 Change-Id: Id29c6c7b7b394cd8e734326c8c7804f3180d67ad Signed-off-by:Azhar Shaikh <azhars@codeaurora.org> Signed-off-by:
Mekala Natarajan <mekalan@codeaurora.org> (cherry picked from commit 2dbcb4dd)